Appendix X: File collections#

Here, some concrete use-cases of entity-linked file collections are listed using descriptive tables, organized by modality.

The tables in this appendix catalog applications where the use of a file collection is REQUIRED.

Certain entities interlink the files in a file collection through a metadata field. Unlike other common entities (for example run), they require an iteration over different values of the metadata fields they represent. Please keep the following list of linking entities up-to-date with the file collections included in this appendix:

Magnetic Resonance Imaging#

Anatomy imaging data#

Suffix

Linking entities

Application

Description

VFA

flip

Variable flip angle

The VFA method involves at least two spoiled gradient echo (SPGR) of steady-state free precession (SSFP) images acquired at different flip angles. Depending on the provided metadata fields and the sequence type, data may be eligible for DESPOT1, DESPOT2 and their variants (Deoni et al. 2005).

IRT1

inv, part

Inversion recovery T1 mapping

The IRT1 method involves multiple inversion recovery spin-echo images acquired at different inversion times (Barral et al. 2010).

MP2RAGE

flip, inv, echo, part

Magnetization prepared two gradient echoes

The MP2RAGE method is a special protocol that collects several images at different flip angles and inversion times to create a parametric T1map by combining the magnitude and phase images (Marques et al. 2010).

MESE

echo

Multi-echo spin-echo

The MESE method involves multiple spin echo images acquired at different echo times and is primarily used for T2 mapping. Please note that this suffix is not intended for the logical grouping of images acquired using an Echo Planar Imaging (EPI) readout.

MEGRE

echo

Multi-echo gradient-echo

Anatomical gradient echo images acquired at different echo times. Please note that this suffix is not intended for the logical grouping of images acquired using an Echo Planar Imaging (EPI) readout.

MTR

mt

Magnetization transfer ratio

This method is to calculate a semi-quantitative magnetization transfer ratio map.

MTS

flip, mt

Magnetization transfer saturation

This method is to calculate a semi-quantitative magnetization transfer saturation index map. The MTS method involves three sets of anatomical images that differ in terms of application of a magnetization transfer RF pulse (MTon or MToff) and flip angle (Helms et al. 2008).

MPM

flip, mt, echo, part

Multi-parametric mapping

The MPM approaches (a.k.a hMRI) involves the acquisition of highly-similar anatomical images that differ in terms of application of a magnetization transfer RF pulse (MTon or MToff), flip angle and (optionally) echo time and magnitue/phase parts (Weiskopf et al. 2013). See here for suggested MPM acquisition protocols.

Fieldmap data#

Suffix

Meta-data relevant entity

Application

Description

TB1DAM

flip

Double-angle B1+ mapping

The double-angle B1+ method (Insko and Bolinger 1993) is based on the calculation of the actual angles from signal ratios, collected by two acquisitions at different nominal excitation flip angles. Common sequence types for this application include spin echo and echo planar imaging.

TB1EPI

flip, echo

B1+ mapping with 3D EPI

This B1+ mapping method (Jiru and Klose 2006) is based on two EPI readouts to acquire spin echo (SE) and stimulated echo (STE) images at multiple flip angles in one sequence, used in the calculation of deviations from the nominal flip angle.

TB1AFI

Please see the qMRI appendix.

Actual Flip Angle Imaging (AFI)

This method (Yarnykh 2007) calculates a B1+ map from two images acquired at interleaved (two) TRs with identical RF pulses using a steady-state sequence.

TB1TFL

Please see the qMRI appendix.

Siemens tfl_b1_map

B1+ data acquired using tfl_b1_map product sequence by Siemens based on the method by Chung et al. (2010). The sequence generates one anatomical image and one scaled flip angle map.

TB1RFM

Please see the qMRI appendix.

Siemens rf_map

B1+ data acquired using rf_map product sequence by Siemens.

TB1SRGE

flip, inv

SA2RAGE

Saturation-prepared with 2 rapid gradient echoes (SA2RAGE) uses a ratio of two saturation recovery images with different time delays, and a simulated look-up table to estimate B1+ (Eggenschwiler et al. 2011). This sequence can also be used in conjunction with MP2RAGE T1 mapping to iteratively improve B1+ and T1 map estimation (Marques & Gruetter 2013).

RB1COR

Please see the qMRI appendix.

B1- field correction

Low resolution images acquired by the body coil (in the gantry of the scanner) and the head coil using identical acquisition parameters to generate a combined sensitivity map as described in Papp et al. (2016).